sinee — 6.2 Function Parameter Table

EM600 High-Performance Vector Control Inverter User Manual 114 Function Name of Function Parameter Description Unit Default Property Code Code 6:

Reverse Constant Speed F19.05 Working Time at Fault h 0 × F19.06 Last Fault Type See F19.00 Parameter Description 0 × F19.07 Output Frequency at Fault Hz 0.00 × F19.08 Output Current at Fault A 0.00 × F19.09 Bus Voltage at Fault V 0 × F19.10 Running Mode at Fault See F19.00 Parameter Description 0 × F19.11 Working Time at Fault h 0 × F19.12 Types of Last Two Faults See F19.04 Parameter Description 0 × F19.13 Output Frequency at Fault Hz 0.00 × F19.14 Output Current at Fault A 0.00 × F19.15 Bus Voltage at Fault V 0 × F19.16 Running Mode at Fault See F19.04 Parameter Description 0 × F19.17 Working Time at Fault h 0 × F30 Position Control Parameter Group F30.00 Position Control Mode 0:Disabled 1:Zero Servo (Frequency Reach Enabled) 2:Zero Servo (Frequency Reach and Terminal Enabled ) 3:Spindle Orientation 4:Feed 0 〇 F30.01 Zero Servo Start Frequency 0.00 - 5.00 Hz 0.25 ● F30.02 Position loop gain 0.000 - 40.000 1.000 ● F30.03 Not Used - - - - F30.04 Not Used - - - - F30.05 Position Error Limit 0 - 9999 0 ● F30.06 Position Control Upper Limit Frequency 0.00 - Fmax Hz 50.00 ● F30.07 Not Used - - - -