sinee — 6.2 Function Parameter Table

EM600 High-Performance Vector Control Inverter User Manual 115 Function Name of Function Parameter Description Unit Default Property Code Code F30.08 Position Control Deceleration Time 0.00 - 600.00 s 0.50 ● F30.09 Not Used - - - - F30.10 Position Feedback Mode 0: Motor Encoder Position 1: Extra Z Pulse Position 2:

Spindle Encoder Position 0 〇 F30.11 Position Complete Range 0 - 65535 10 ● F30.12 Position Complete Time 0 - 10000 ms 200 ● F30.13 Position Acknowledging time 0 - 1000 ms 10 ● F30.14 Spindle Orientation Position 1 0 - 65535 0 ● F30.15 Spindle Orientation Position 2 0 - 65535 0 ● F30.16 Spindle Orientation Position 3 0 - 65535 0 ● F30.17 Spindle Orientation Position 4 0 - 65535 0 ● F30.18 Spindle Orientation Position 5 0 - 65535 0 ● F30.19 Spindle Orientation Position 6 0 - 65535 0 ● F30.20 Spindle Orientation Position 7 0 - 65535 0 ● F30.21 Spindle Orientation Position 8 0 - 65535 0 ● F30.22 Spindle Orientation Speed 0.00 - Upper Limit Frequency Hz 10.00 ● F30.23 Spindle Orientation Direction 0:

Current Direction 1: Shortest Distance 0 〇 F30.24 Spindle clamp locking delay time 0 - 30000 ms 0 〇 F30.25 Spindle Encoder Type 0: ABZ Incremental Encoder 1: UVW Incremental Encoder 2: UVW Wire-Saving Encoder 3: Not Used 4: Rotary Transformer 0 〇 F30.26 Spindle Encoder Resolution 1 - 65535 1024 〇 F30.27 Not Used - - - - F30.28 Not Used - - - -