EM600 High-Performance Vector Control Inverter User Manual 7 Parameter Description 7.1 F00 Group: General Parameter F00.01=0: V/F control (VVF) Inverter is applicable for the occasions when multiple motors are driven by a single inverter or it is not required for quick response or high precision. F00.01=1: Sensorless Vector Control (SVC) Inverters under sensorless vector control are usually applied to high-performance control occasions and one inverter can only drive one motor. Loads include machine tool, centrifuge, wire-drawing machine and injection moulding machine. F00.01=2:
Feedback Vector Control (FVC) In addition to installing an encoder for motor, EM600 inverter under FVC control must select a PG card matching with the encoder (see 11.4.2 PG Card Configuration Plan or Appendix II). It is suitable for high-accuracy speed control or torque control. An inverter can drive one motor only, for example high-speed papermaking machine, hoisting machine, elevator and other loads. F00.02=0: Keypad Control (LOC/REM indicator on) Start and stop of inverter will be controlled with , Under no fault, press M.K to enter jog running mode or press to enter running of keypad. mode.
When green LED above RUN button is always on, it means that inverter is running; when green LED above RUN button flickers, it means that inverter is in ramp-to-stop status. No matter whether reference input of control mode is speed or torque, inverter always runs at jog input speed control mode as long as jog is enabled. 118 Function Name of Parameter Description Unit Default Property Code Function Code F00.01 Drive Control Mode of Motor 1 0: V/F control (VVF) 1: Sensorless Vector Control (FVC) 2. Feedback Vector Control (FVC) 0 〇 1. Before running in vector control mode, inverter needs to autotune motor parameters to obtain correct motor parameters and enhance the control performance. 2.
While using vector control mode, inverter can only have one motor. Motor and inverter shall not be much different from each other in capacity, otherwise control performance will decrease or the system can not work normally. Function Name of Parameter Description Unit Default Property Code Function Code F00.02 Command Source 0: Keypad Control (LOC/REM indicator on) 1: Terminal Control (LOC/REM indicator off) 2: Communication Control (LOC/REM indicator flickers) 0 〇 RUN STOP RESET M.K RUN