EM600 High-Performance Vector Control Inverter User Manual No matter whether reference input of control mode is speed or torque, inverter always runs at jog input speed control mode as long as jog is enabled. F00.02=1: Terminal Control (LOC/REM indicator off) Start/stop control terminal defined through F02.00 - F02.06 controls start and stop of inverter; detailed configurations of terminal control are defined through F00.03. F00.02=2: Communication Control (LOC/REM indicator flickers) Host controller controls inverter to start and stop through RS485 communication interface. See 7000H in 12.3.4 Allocation of Register Address. Terminal RUN:
Xi=1, Run Terminal “RUN” Terminal Forward/Reverse (F/R): Xi=2, Direction R/F There are two terminal control modes, 2-wire sequence and 3-wire sequence. 2-Wire Sequence: F00.03=0: Terminal RUN, Forward/Reverse (F/R) ON/OFF of terminal RUN controls start and stop of inverter and OFF/ON of terminal F/R controls forward/reverse of inverter; if F00.21 is set as 1 and reverse is prohibited, terminal F/R is disabled. By selecting ramp-to-stop for stop mode, logic diagram is shown in Figure 7-1 (b). F00.03=1: Terminal RUN forward, F/R reverse ON/OFF of terminal RUN controls forward running and stop of inverter and ON/OFF of terminal F/R controls reverse and stop of inverter.
If terminals RUN and F/R are on, inverter stops. If reverse is prohibited, terminal F/R is disabled. When selecting ramp-to-stop, control logic of inverter Forward/Reverse is shown in Figure 7-1 (d). 119 Final command source is also determined by either “24: Switch Run Command to Keypad” or “25: Switch Run Command to Communication”: when input function “24: Switch Run Command to Keypad” is enabled, present command source is “Keypad Control”; when input function “25: Switch Run Command to Communication” is enabled, present command source is “Communication Control”; otherwise, final command source is determined through F00.02.
Function Name of Parameter Description Unit Default Property Code Function Code F00.03 Terminal Control Mode Options 0: Terminal RUN for running, Forward/Reverse (F/R) 1: Terminal RUN for forward, F/R reverse 2: Terminal RUN for forward, Xi stop, F/R reverse 3: Terminal RUN for running, Xi stop Forward/Reverse (F/R) 0 〇