EM600 High-Performance Vector Control Inverter User Manual F00.04=0: Numeric frequency setting F00.07 Main frequency A is determined through numeric frequency setting F00.07. F00.04=1: AI1 F00.04=2: AI2 F00.04=3: AI3 F00.04=4: AI4 (Expansion Card) Main frequency A is determined through AI (percentage) * F00.16 (or F14.78). AI1 is 0 V to 10 V voltage input; AI2/AI3 can be either 0 V to 10 V voltage input or 0 mA to 20 mA current input. Specific options can be made through terminal of terminal plate S4/S5. AI4 is -10 V to 10 V voltage input and IO expansion card (EC-IO-A1) of SINEE is required.
The percentage corresponding to physical quantity input of AI terminal is set through F02.31 - F02.56. 100.00% corresponds to the value set through F00.16 (or F14.78) (Maximum Frequency). F00.04=5: High-Frequency Pulse Input (X7) Main frequency A is determined through HDI (percentage) * F00.16. X7 can be also used as high-frequency pulse input (terminal function F02.06 shall be set as “40: Pulse Input”), with set frequency range of 0.00 to 100.00 kHz and set voltage range of 12 to 48 V. Percentage of terminal input pulse frequency shall be set through F02.26 - F02.29 and 100.00% is the percentage set through F00.16 (Maximum Frequency).
The percentage corresponding to physical quantity input of AI terminal is set through F02.31 - F02.36. 100.00% corresponds to the value set through F00.16 (Maximum Frequency). F00.04=6or7: Main Frequency Communication Setting Main frequency A is determined through communication control, etc. If inverter is under master-slave communication control (F10.05=1) and present inverter is a slave (F10.06=0), main frequency A is set as “700 FH (Master-Slave Communication Setting) * F00.16 (or F14.78) (Maximum Frequency) * F10.08 (Receiving Proportionality Factor of Slave)”. Range of 700 FH is -100.00% to 100.00%. See Table 12-2 for details. For general communication (F10.05=0):
a) F00.04=6 Main Frequency Communication Percentage Setting. Main frequency source A is set as “7001H (communication setting of main channel frequency A) * F00.16 (or F14.78) (Maximum Frequency)”. b) F00.04=7 Main Frequency Communication Direct Setting. Main frequency source A is set as “7015H (communication setting of main channel frequency A)”. The range of 7001H is -100.00% to 100.00%. The range of 7015H is 0.00 to F00.16 (Maximum Frequency). See Table 12-2 for details. The final main frequency source A is also set through DI terminal status: Table 7-1 Setting of Main Frequency Source A 122 Terminal Function Description Priority 11 - 14:
Preset Speed Terminals 1 - 4 It is preset speed when any terminal is enabled (F08.00 - F08.14). 1 51: Switch Main Frequency Source to Numeric If enabled, numeric frequency is determined by F00.07, for which refer to description of 2