EM600 High-Performance Vector Control Inverter User Manual 182 Function Name of Function Parameter Description Unit Default Property Code Code F08.19 Setting of Preset Speed 1 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2: Acceleration/Deceleration Time 3 3: Acceleration/Deceleration Time 4 0 ● F08.20 Running Time of Preset Speed 1 0.0 - 6000.0 5.0 ● F08.21 Setting of Preset Speed 2 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2:
Acceleration/Deceleration Time 3 3: Acceleration/Deceleration Time 4 0 ● F08.22 Running Time of Preset Speed 2 0.0 - 6000.0 5.0 ● F08.23 Setting of Preset Speed 3 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2: Acceleration/Deceleration Time 3 3: Acceleration/Deceleration Time 4 0 ● F08.24 Running Time of Preset Speed 3 0.0 - 6000.0 5.0 ● F08.25 Setting of Preset Speed 4 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2:
Acceleration/Deceleration Time 3 3: Acceleration/Deceleration Time 4 0 ● F08.26 Running Time of Preset Speed 4 0.0 - 6000.0 5.0 ● F08.27 Setting of Preset Speed 5 Ones Place: Running Direction 0: Forward 0 ●