sinee — 7.9 F08 Group: Preset Speed and Simple PLC Parameter

EM600 High-Performance Vector Control Inverter User Manual 184 Function Name of Function Parameter Description Unit Default Property Code Code Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2: Acceleration/Deceleration Time 3 3: Acceleration/Deceleration Time 4 F08.36 Running Time of Preset Speed 9 0.0 - 6000.0 5.0 ● F08.37 Setting of Preset Speed 10 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2: Acceleration/Deceleration Time 3 3:

Acceleration/Deceleration Time 4 0 ● F08.38 Running Time of Preset Speed 10 0.0 - 6000.0 5.0 ● F08.39 Setting of Preset Speed 11 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2: Acceleration/Deceleration Time 3 3: Acceleration/Deceleration Time 4 0 ● F08.40 Running Time of Preset Speed 11 0.0 - 6000.0 5.0 ● F08.41 Setting of Preset Speed 12 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2: Acceleration/Deceleration Time 3 3:

Acceleration/Deceleration Time 4 0 ● F08.42 Running Time of Preset Speed 12 0.0 - 6000.0 5.0 ● F08.43 Setting of Preset Speed 13 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 0 ●