EM600 High-Performance Vector Control Inverter User Manual Under default applications, circular display queue only displays some commonly used options, respectively output frequency (F18.00), set frequency (F18.01), output current (F18.06), output voltage (F18.08) and DC bus voltage (F18.08). If other parameters are required for display, please set these parameters as 1; if not, set them as 0. ★ Please pay enough attention when retaining some function codes. Inverter output is mostly displayed in frequency.
To get to know present load speed (F18.14), user may set present parameter according to actual applications, so as to convert frequency output into speed output; as a result, F18.14 would be used to display present load speed. If F12.09=30.00 (this value is relative to pole-pairs, device transmission ratio, etc.), then output frequency 0.00 - 50.00 Hz correspond to load speed 0 - 1500 rpm. UP/DOWN can be classified into keypad UP/DOWN and terminal UP/DOWN, which can be enabled individually and simultaneously. Keypad UP/DOWN: Only enabled at the level 0 monitoring menu, which is under control of on keypad.
By pressing / under the monitoring menu, offset frequency increases/decreases at the rate set through F12.10; at this time, keypad displays “F18.15: UP/DOWN Offset Frequency” and the final frequency is the sum of set frequency and offset frequency. After releasing the button for 1s, keypad displays normally. Terminal UP/DOWN: By setting the numeric input terminal as corresponding function, inverter is under terminal control. When terminal UP/DOWN is on, offset frequency increases/decreases at the rate set through F12.10 and final frequency is the sum of set frequency and offset frequency. Keypad display remains unchanged during the period.
★ When keypad UP and terminal down (or keypad DOWN and terminal UP) are enabled at the same time, offset frequency fluctuates due to different valid time points, although acceleration/deceleration speed does not change. It is a normal phenomenon. 205 Function Code Name of Function Code Parameter Description Unit Default Property F12.09 Load Speed Display Factor 0.01 - 600.00 30.00 ● Function Name of Function Parameter Description Unit Default Property Code Code F12.10 UP/DOWN Acceleration/Decel eration Rate 0.00: Automatic Rate 0.01 - 500.00 Hz/s 5.00 〇 F12.11 UP/DOWN Offset Clear 0: Not to Clear 1: Clear at Non-Running Status 2:
Clear at Disabled UP/DOWN 1 〇 F12.12 Power Failure Save of UP/DOWN Offset 0: Disabled 1: Enabled (only at modified offset) 0 〇 Function Code Name of Function Code Parameter Description Unit Default Property F12.13 Kilowatt-Hour Meter Clear 0: Not to Clear 1: Clear 0 ●