sinee — 7.18 F17 Group: Virtual I/O Function Parameter

EM600 High-Performance Vector Control Inverter User Manual In terms of functions, VX1 - VX8 are basically the same; they do not have an actual physical terminal, but they all have positive/negative logic function. VX1 - VX4 have delay function, with the same terminal status confirmation method; they can be set respectively. An example is given to VX1 in the following part.  If F17.09=xxxxxxx0, VX1 status and VY1 output status are the same. As mentioned above, virtual input terminal has the same status as virtual output terminal. At this time, it needs to be used together with virtual output terminal.

If F17.19=16 and F17.28=xxxx xxx1 (VY1 output status is determined by output function status) under default applications, then when “16: Length Reach” is enabled, VY1 is enabled and VX1 is enabled as well; at this time, setting this function as per VX1 (assuming 39: Length Clear) to complete corresponding operations (clear length count and reset VY1). Now, fixed length count function can start again to realize the repeated processing requirements. If time interval is needed for repeated processing times, we can realize this function by VX1 delay.  If F17.09=xxxxxxx1, VX1 status of is determined by bit0 of function code F17.10. Status of virtual input terminals can be set by function codes.

This method is mainly used 225 Function Name of Function Code Parameter Description Unit Default Property Code 1:

Negative Logic, Disabled at On/Enabled at Off F17.11 VX1 Effective Delay Time 0.000 - 30.000 s 0.000 ● F17.12 VX1 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● F17.13 VX2 Effective Delay Time 0.000 - 30.000 s 0.000 ● F17.14 VX2 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● F17.15 VX3 Effective Delay Time 0.000 - 30.000 s 0.000 ● F17.16 VX3 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● F17.17 VX4 Effective Delay Time 0.000 - 30.000 s 0.000 ● F17.18 VX4 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● Name of Function Code Function Parameter Description Unit Default Property Code F17.09 VX1 - VX8 Status Setting D7 D6 D5 D4 D3 D2 D1 D0 000 00000 〇 VX8 VX7 VX6 VX5 VX4 VX3 VX2 VX1 0:

VXn Is Same as VYn Output 1: Status to be Set by F17.10 F17.10 VX1 - VX8 Status Setting D7 D6 D5 D4 D3 D2 D1 D0 000 00000 ● VX8 VX7 VX6 VX5 VX4 VX3 VX2 VX1 0: Disabled 1: Enabled