EM600 High-Performance Vector Control Inverter User Manual 230 Function Name of Parameter Description Unit Code Function Code ★ 0: disabled; 1: enabled. F18.25 Output Terminal Status Display present active status of input terminals R1/R2/Y1/Y2. The five-digit nixie tube will display the following information from left to right: Actual display: 01010. Y3 R2 1 Y2 Y1 0/1 0/1 0/1 0/1 0/1 ★ Numeric output terminal Y3 is an expansion card (EC-IO-A1) terminal. Please perform configuration before use. ★ 0: disabled; 1: enabled. F18.26 AI1 Used to display standard value of present analog input channel 1 (AI1) corresponding to 100.0%. Range: 0.0 - 100.0.
% F18.27 AI2 Used to display standard value of present analog input channel 2 (AI2) corresponding to 100.0%. Range: 0.0 - 100.0. % F18.28 AI3 Used to display standard value of present analog input channel 3 (AI3) corresponding to 100.0%. Range: 0.0 - 100.0. % F18.29 AI4 Used to display standard value of present analog input channel 4 (AI4) corresponding to 100.0%. Range: -100.0 - 100.0. ★ Analog input terminal AI4 is an expansion card (EC-IO-A1) terminal. Please perform configuration before use. % F18.30 Communication Setting Not used % F18.31 High-Speed Pulse Input Frequency: kHz Used to display input pulse frequency of present high-speed pulse input channel HDI (X7). Minimum resolution:
0.01 kHz. Range: 0.00 - 100.00. kHz F18.32 High-Speed Pulse Input Frequency: Hz Used to display input pulse frequency of present high-speed pulse input channel HDI (X7). Minimum resolution: 1 kHz. Range: 0 - 65535. If actual input frequency > 65535 Hz, display value is 65535. Hz F18.33 Count Value Used to display number of input pulses of present high-speed pulse input channel HDI (X7). See F16.03 and F16.04. Range: 0 - F16.03. F18.34 Actual Length Used to display actual length of workpiece being processed (by transformation from HDI (X7) as per relevant setting) of input pulses of present high-speed pulse input channel HDI (X7). See F16.03 and F16.04. Range: 0 - F16.01.
m F18.35 Remaining Time of Timed Run Used to display remaining time of timed run. See F16.05. Range: 0.0 - F16.05. min