EM600 High-Performance Vector Control Inverter User Manual 231 Function Name of Parameter Description Unit Code Function Code F18.36 Position of Rotor of Synchronous Motor Position of rotor of synchronous motor. Range: 0.0 - 359.9. ° F18.37 Rotary Transformer Position Used to display rotary transformer position. Range: 0 - 4095. F18.38 Motor Temperature Used to display motor temperature collected by analog channel 4 (AI4). Range 0 – 200. ℃ F18.39 VF Separation Target Voltage Used to display VF separation target voltage in real time. Range: 0.0 - Motor Rated Voltage. V F18.40 VF Separation Output Voltage Used to display VF separation output voltage in real time. Range:
0.0 - Motor Rated Voltage.
V F18.41 - F18.42 Not Used - - F18.43 Zero Servo Position Offset 0 - 65535 F18.44 - F18.50 Not Used - - F18.51 PID Output Process PID is running, display the PID output value (%) % F18.52 Spindle Orientation Setting Position Display the setting position on spindle orientation F18.53 Spindle Orientation Current Position Display the current position on spindle orientation F18.54 Feed Setting High Byte Display the feed setting value of high Byte on spindle orientation F18.55 Feed Setting Low Byte Display the feed setting value of low Byte on spindle orientation F18.56 Feed Current High Byte Display the feed current value of high Byte on spindle orientation F18.57 Feed Current Low Byte Display the feed current value of low Byte on spindle orientation F18.58 Feedback Pulse High Byte Display the encoder feedback pluse value of high byte (HEX) F18.59 Feedback Pulse Low Byte Display the encoder feedback pluse value of low byte (HEX)