EM600 High-Performance Vector Control Inverter User Manual 7.20 F19 Group: Fault Record Parameter This group of parameters can be used for viewing types of last three faults and status of inverter at fault, but can not be operated. Function codes related to the information about last fault: Function codes related to the information about last fault: Function codes related to the information about last two faults: 232 Function Code Name of Function Parameter Description Unit Default Property Code F19.00 Last Fault Type Display last fault type. See chapter 9. 0 × F19.01 Output Frequency at Fault Used to display output frequency at last fault.
Hz 0.00 × F19.02 Output Current at Fault Used to display output current at last fault. A 0.00/0.0 × F19.03 Bus Voltage at Fault Used to display bus voltage at last fault. V 0 × F19.04 Running Mode at Fault Used to display running status at last fault. See chapter 9. 0 × F19.05 Working Time at Fault Used to display working time at last fault. h 0 × Function Code Name of Function Code Parameter Description Unit Default Property F19.06 Last Fault Type Display last fault type. See chapter 9. 0 × F19.07 Output Frequency at Fault Display output frequency at last fault. Hz 0.00 × F19.08 Output Current at Fault Display output current at last fault.
A 0.00/0.0 × F19.09 Bus Voltage at Fault Display bus voltage at last fault. V 0 × F19.10 Running Mode at Fault Used to display running status at last fault. See chapter 9. 0 × F19.11 Working Time at Fault Used to display working time at last fault. h 0 × Function Name of Function Code Parameter Description Unit Default Property Code F19.12 Types of Last Two Faults Display types of last two faults. See chapter 9. 0 × F19.13 Output Frequency at Fault Display output frequency at last two faults. Hz 0.00 × F19.14 Output Current at Fault Display output current at last two faults. A 0.00 /0.0 × F19.15 Bus Voltage at Fault Display bus voltage values at last two faults. V 0 ×