EM600 High-Performance Vector Control Inverter User Manual ★ Frequently changed function codes of inverter can not complete this with 0x10 to avoid damaging inverter. Refer to 12.3.3.5 for details. 12.3.4 Allocation of Register Address Table 12-2 MODBUS Protocol Register Address Definitions 260 Request Response Field Name (0x) Field Name (normal) (0x) Field Name (abnormal) (0x) Register Value Lo 01 (F03.00) Register Value Hi 00 (F03.01) Register Value Lo 03 (F03.01) Address Space Description For function codes FXX.YY, their high addresses are in hexadecimal format of XX and their low addresses are in hexadecimal format of YY. For example F12.03, its address is 0C03H (12D=0CH, 03D=03H).
Function Code 0000H - 6F63H 7000H Control Word 0000H Disabled Command 0001H Forward Running 0002H Reverse Running 0003H Forward JOG 0004H Reverse JOG 0005H Ramp-To-Stop 0006H Rapid Stop 0007H Coast-to-Stop 0008H Fault Reset 0009H +/-Input Switch 000BH JOG Stop Other - 00FFH Not Used Control 7001H Main Channel Frequency A Communication Percentage Setting -100.00% - 100.00% (100%=maximum frequency) Command (Write Only) 7002H Auxiliary Channel Frequency B Communication Percentage Setting -100.00% - 100.00% (100%=maximum frequency) 7000H - 71FFH 7003H Torque Communication Setting -200.00% - 200.00% (100%=Numeric Torque Setting Reference) 7004H Process PID Communication Setting -100.00% - 100.00% 7005 H Process PID Feedback Communication Setting -100.00% - 100.00% 7006H VF separation mode voltage setting 0.00% - 100.00% (Numeric Setting Reference) 7007H - 7009H Not Used