EM600 High-Performance Vector Control Inverter User Manual 62 Function Name of Function Parameter Description Unit Default Property Code Code F01.16 Induction Motor Field Weakening Factor 3 10.00 - 100.00 % 75.00 〇 F01.17 Induction Motor Field Weakening Factor 4 10.00 - 100.00 % 72.00 〇 F01.18 Induction Motor Field Weakening Factor 5 10.00 - 100.00 % 70.00 〇 F01.19 Stator Resistor of Synchronous Motor 1 - 60000 (Motor Rated Power ≤ 75kW) 0.1 - 6000.0 (Motor Rated Power > 75kW) mΩ Up To Specific Model 〇 F01.20 d-Shaft Inductance of Synchronous Motor 0.01 - 600.00 (Motor Rated Power ≤ 75kW) 0.001 - 60.000 (Motor Rated Power > 75kW) mH Up To Specific Model 〇 F01.21 q-Shaft Inductance of Synchronous Motor 0.01 - 600.00 (Motor Rated Power ≤ 75kW) 0.001 - 60,000 (Motor Rated Power > 75kW) mH Up To Specific Model 〇 F01.22 Back Electromotive Force of Synchronous Motor 10.0 - 2000.0 (Back Electromotive Force of Rated Rotation Speed) V Up To Specific Model 〇 F01.23 Initial Electric Angle of Synchronous Motor 0.0 - 359.9 (Synchronous motor enabled) 〇 F01.24 Encoder Type 0:
ABZ Incremental Encoder 1: UVW Incremental Encoder 2: UVW Wire-Saving Encoder 3: Not Used 4: Rotary Transformer 0 〇 F01.25 Encoder Resolution 1 - 65535 1024 〇 F01.26 Phase Angle of Zero Pulse of Encoder 0.0 - 359.9° 0.0 〇 F01.27 AB Pulse Phase Sequence 0: Forward 1: Reverse 0 〇 F01.28 Phase Sequence of UVW Encoder 0: Forward 1: Reverse 0 〇 F01.29 UVW Initial Offset Phase Angle 0.0 - 359.9° 0.0 〇 F01.30 Rotary Transformer Pole-Pairs 1 - 65535 1 〇 F01.31 Not Used F01.32 Speed Feedback Disconnection Detection Time 0.0 - 10.0 (0.0: Speed Feedback Disconnection Detection Disabled) 0.0 〇