EM600 High-Performance Vector Control Inverter User Manual 63 Function Name of Function Parameter Description Unit Default Property Code Code F01.33 Filter Time of Speed Feedback 0.000 - 0.100 s 0.002 〇 F01.34 Motor Parameter Autotuning 0: No Autotuning 1: Stationary Autotuning of Induction Motor 2: Rotational Autotuning of Induction Motor 3: Not Used 11: Stationary Autotuning of Synchronous Motor 12: Rotational Autotuning of Synchronous Motor 13: Autotuning of Encoder of Synchronous Motor 0 〇 F02 Input Terminal Function Group F02.00 X1 Numeric Input Function 0: No Function 1: Run Terminal “RUN” 2: Direction R/F 3:Wire Sequence Stop Control 4: Forward JOG (FJOG) 5: Reverse JOG (RJOG) 6:
Terminal UP 7: Terminal DOWN 8: Clear UP/Down Offset 9: Coast to Stop 10: Fault Reset 11: Preset Speed Terminal 1 12: Preset Speed Terminal 2 13: Preset Speed Terminal 3 14: Preset Speed Terminal 4 15: Preset PID Terminal 1 16: Preset PID Terminal 2 17: Preset Torque Terminal 1 18: Preset Torque Terminal 2 19: Acceleration/Deceleration Time Terminal 1 20: Acceleration/Deceleration Time Terminal 2 20: Acceleration/Deceleration Time Terminal 2 22: Pause Operation 23: External Fault Input 24:
Switch Run Command to 1 〇 F02.01 X2 Numeric Input Function 2 〇 F02.02 X3 Numeric Input Function 11 〇 F02.03 X4 Numeric Input Function 12 〇 F02.04 X5 Numeric Input Function 13 〇 F02.05 X6 Numeric Input Function 14 〇 F02.06 X7 Numeric Input Function 10 〇 F02.07 AI1 Numeric Input Function 0 〇 F02.08 AI2 Numeric Input Function 0 〇 F02.09 AI3 Numeric Input Function 0 〇 F02.10 AI4 Numeric Input Function (Expansion Card) 0 〇 F02.11 X8 Numeric Input Function (Expansion Card) 0 〇 F02.12 X9 Numeric Input Function (Expansion 0 〇