EM600 High-Performance Vector Control Inverter User Manual 70 Function Name of Function Parameter Description Unit Default Property Code Code 19: PID Feedback Upper Limit Reach 20: PID Feedback Lower Limit Reach 21: Analog Quantity Level Detection ADT1 22: Analog Quantity Level Detection ADT2 23: Zero Servo 24: Undervoltage Status 25: Motor Overload Pre-alarming 26: Set Time Reach 27: Run at Zero Speed 28 - 35: Not Used 36: Position Fix 37 – 68: Not Used 69: FDT1 Lower Limit Frequency (Pulse) 70: FDT2 Lower Limit Frequency (Pulse) 71: FDT1 Lower Limit Frequency (Pulse, Disabled when JOG) 72:
FDT2 Lower Limit Frequency (Pulse, Disabled when JOG) F03.05 Output Signal Type D7 D6 D5 D4 D3 D2 D1 D0 *0000 〇 * * * * R2 R1 Y2 Y1 0: Level 1: Monopulse F03.06 Positive/Negative Logic of Numeric Output D7 D6 D5 D4 D3 D2 D1 D0 00000 〇 * * * Y3 R2 R1 Y2 Y1 0: Positive Logic, Enabled at On/Disabled at Off 1: Negative Logic, Disabled at On/Enabled at Off F03.07 Y2 Output Type 0: Common Numeric Output 0 〇 1: High-Frequency Pulse Output F03.08 Output Status Control at JOG D7 D6 D5 D4 D3 D2 D1 D0 00000 〇 * * * REV FD T2 FDT1 FA R RU N 0: Enabled at JOG 1: Disabled at JOG F03.09 Y1 Effective Delay Time 0.000 - 30.000 s 0.000 ● F03.10 Y1 Ineffective Delay 0.000 - 30.000 s 0.000 ●