EM600 High-Performance Vector Control Inverter User Manual 71 Function Name of Function Parameter Description Unit Default Property Code Code Time F03.11 Y2 Effective Delay Time 0.000 - 30.000 s 0.000 ● F03.12 Y2 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● F03.13 R1 Effective Delay Time 0.000 - 30.000 s 0.000 ● F03.14 R1 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● F03.15 R2 Effective Delay Time 0.000 - 30.000 s 0.000 ● F03.16 R2 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● F03.17 Y1 Monopulse Output Time 0.000 - 30.000 s 0.250 ● F03.18 Y2 Monopulse Output Time 0.000 - 30.000 s 0.250 ● F03.19 R1 Monopulse Output Time 0.000 - 30.000 s 0.250 ● F03.20 R2 Monopulse Output Time 0.000 - 30.000 s 0.250 ● F03.21 Analog Output M1 0:
Running Frequency (absolute value) 1: Set Frequency (absolute value) 2: Output torque (absolute value) 3: Set Torque (absolute value) 4: Output Current 5: Output Voltage 6: Bus voltage 7: Output power 8: AI1 9: AI2 10: AI3 11: AI4 (Expansion Card) 12: High-Frequency Pulse Input (100.00% Corresponding to Maximum Frequency, 0.00% Corresponding to Minimum Frequency) 13: Not Used 14: Value of Count 15: Value of Length 16-29: Not Used 0 〇 F03.22 Analog Output M2 2 〇 F03.23 Y2 High-Frequency Pulse Output Function 11 〇 F03.24 100% Frequency of 0.00 - 100.00 kHz 50.00 ●