sinee — 9.2 Table of functional parameters

User Guide of EM730 Series Inverter 77 weakening voltage F06.23 Maximum field weakening current of synchronous motor 0.0-150.0 (100.0 is the rated current of the motor) % 100.0 ● F06.24 Proportional gain of flux weakening regulator 0.00 - 10.00 0.50 ● F06.25 Integral time of flux weakening regulator 0.01 - 60.00 s 2.00 ● F06.26 MTPA control option of synchronous motor 0: Invalid 1:

valid 1 〇 F06.27 Self-learning gain at initial position 0 - 200 % 100 ● F06.28 Frequency of low frequency band of injection current 0.00-100.00 (100.00 is the rated frequency of the motor) % 10.00 ● F06.29 Injection current of low frequency band 0.0-60.0 (100.0 is the rated current of the motor) % 20.0 40.0-(F16.0 0=2) ● F06.30 Regulator gain of low frequency band of injection current 0.00 - 10.00 0.50 ● F06.31 Regulator integral time of low frequency band of injection current 0.00 - 300.00 ms 10.00 ● F06.32 Frequency of 0.00-100.00 (100.00 is the rated frequency of the motor) % 20.00 ●