User Manual of EM730/EM730E Series Inverter When the set frequency of the inverter is lower than the lower frequency limit (F00.19), the running status depends on the function code F15.33. In order to use the fan reasonably, the fan system has three running modes, depending on the fan control function code (F15.34). The specific running mode of the fan is shown in Table 7-23. Table 7-23 Details of Fan Operation ★ When “2: intelligent operation, subject to temperature control” is selected, make sure that the temperature detection module of the inverter works properly.
When the input voltage of the inverter is lower than the output voltage, you can increase the overmodulation intensity to improve the bus voltage utilization and thus increase the upper limit of output voltage. When F15.35=1.10, the upper limit of output voltage can be increased by 10%, thus reducing the output current under heavy loads, but the current harmonics will 263 Function Default Function code name Parameter description Unit Attribute code setting F15.33 Operating mode with set frequency less than lower frequency limit 0: running at the lower frequency limit 1: Shutdown 0 〇 Function Function code Default Parameter description Unit Attribute code name setting F15.34 Fan control 0:
running after power-on 1: running at startup 2: intelligent operation, subject to temperature control 1 〇 Fan control Fan operation 0: running after power-on When the inverter is powered on, the fan will start running. 1: running at startup When the inverter starts running, the fan will start running. When this parameter is set to 1 min, the fan will stop running. 2: intelligent operation, subject to temperature control When the temperature of the inverter is greater than 45 °C, the fan will start running; when the temperature of the inverter is less than 40 °C, the fan will stop running; and when the temperature of the inverter is in between the two values, the fan will remain unchanged.
Function Default Function code name Parameter description Unit Attribute code setting F15.35 Overmodulation intensity 1.00 - 1.10 1.05 ●