sinee — EM730 User Manual

User Manual of EM730/EM730E Series Inverter 278 X5 X4 X3 X2 X1 0/1 0/1 0/1 0/1 0/1 The actual display effect is: 00000. ★: “0” means that the current terminal function is invalid; and “1” means that the current terminal function is valid. F18.23 Digital input terminal status 2 Display the current valid status of the input terminals AI1 and AI2. The five-bit digit tubes from left to right are: * AI2 AI1 * * 0/1 0/1 0/1 0/1 0/1 The actual display effect is: 0000. ★: The analog input terminals AI1 and AI2 of the EM730/EM730E series inverter can be used for digital input only. “0” means that the current terminal function is invalid; and “1” means that the current terminal function is valid.

F18.25 Output terminal state Display the current valid status of the output terminals R1/Y1. The five-bit digital tubes from left to right are: * * R1 * Y1 0/1 0/1 0/1 0/1 0/1 The actual display effect is: 000. “0” means that the current function terminal is invalid; and “1” means that the current function terminal is valid. F18.26 AI1 Display the per-unit value of the current analog input channel 1 (AI1) relative to 100.0%. Scope: -100.0 - 100.0 % F18.27 AI2 Display the per-unit value of the current analog input channel 2 (AI2) relative to 100.0%. Scope: 0.0 - 100.0. % F18.30 Reserved F18.31 High-frequency pulse input frequency:

kHz 0.00-100.00 kHz F18.32 High-frequency pulse input frequency: Hz 0~65535 Hz F18.33 Count value 0~65535 F18.34 Actual length 0~65535 m F18.35 Remaining time of regular running Display the remaining time of regular running. For specific function. see the description of the F16.05 regular running function. Scope: 0.0 - F16.05. min F18.36 Rotor position of synchronous 0.0~359.9°