User Manual of EM730/EM730E Series Inverter The running status of EM730/EM730E series inverters during protection is explained in Table 7-25: Table 7-25 List of Running Statuses during Protection 7.21 F27 winding and unwinding application macro parameter group F27.00=0 Winding mode: This mode can be used for winding. After the default settings are restored, the parameters will be restored for winding applications. F27.00=1 Unwinding mode: This mode can be used for unwinding. After the default settings are restored, the parameters will be restored for unwinding applications. F27.00=2 Wire drawing mode: This mode can be used for wire drawing.

After the default settings are restored, the parameters will be restored for wire drawing applications. F27.00=3 Straight wire drawing machine mode: This mode can be used for the straight wire drawing machine. After the default settings are restored, the parameters will be restored for the straight wire drawing machine. 282 E57: Overpressure in pipeline network E57 E58: Under-pressure in pipeline network E58 E68: SVC start failure (synchronous motor) E68 E76:

Short circuit to ground E76 Keyboard Detailed Explanation of display Running Status of Inverter 0 Not running 1 Forward acceleration 2 Reverse acceleration 3 Forward deceleration 4 Reverse deceleration 5 Forward constant speed 6 Reverse constant speed Function Function code Default Parameter description Unit Attribute code name setting F27.00 Application macro 0: Winding mode 1: Unwinding mode 2: Wire drawing mode 3: Straight wire drawing machine mode 0 〇 Function Note 0: Winding 1: Unwinding 2: Wire 3: Straight wire