User Manual of EM730/EM730E Series Inverter disconnection will not be detected. (This function will not be enabled until the output frequency of the inverter must exceed this frequency after the soft start time and be lower than this frequency after deceleration.) The set time of F27.23 is calculated when the wire disconnection is identified. According to the setting of F27.24, the operating frequency in this period is reverse during unwinding and positive during winding. F27.25 and F27.26 are not valid until one output terminal is defined as “brake control” (67# function).

When the output frequency of the inverter drops to the set value of F27.25, the brake control terminal will be valid and maintained (the brake mode 1 is enabled). It will be invalid after the set time of F27.26. When the brake control terminal is valid, the inverter will stop freely. There is no response to the running command when the brake control terminal is valid. If F27.26 is set to 0.0, the brake control terminal will remain valid and can be reset by the brake reset terminal or protection reset terminal.

297 Function Function code Default Parameter description Unit Attribute code name setting F27.23 Time of continuous running after material cutoff 0.0 - 60.0 s 10.0 ● F27.24 Frequency of continuous running after material cutoff 0.00~Fmax Hz 5.00 ● Function Function code Default Parameter description Unit Attribute code name setting F27.25 Brake signal output frequency 0.00~Fup Hz 2.50 ● F27.26 Braking signal duration 0.0-100.0 s 5.0 ● Function Function code Default Parameter description Unit Attribute code name setting F27.27 Minimum frequency of wiring detection 0.00~20.00 Hz 10.00 ● F27.28 Judgment time for invalid cable signal 0.1 - 20.0 s 10.0 ●