User Manual of EM730/EM730E Series Inverter When the input terminal is set to “122: wiring detection signal”, F27.27-F27.29 will be valid. When the output frequency of the inverter reaches the set value of F27.27, wiring detection will be started. If the wiring detection terminal is valid within the set time of F27.28, the wiring switch will be considered invalid. If the wiring detection terminal is always valid within the set time of F27.29, the wiring pole will stop moving. If the wiring pole protection is detected, the inverter will report E44 protection and stop freely. The set time of this function is the filtering time of material cutoff detection.

It is valid simultaneously for automatic material cutoff detection and external material cutoff detection. This function code is used to view the current feedforward gain. Chapter 8 Motor Parameter Self-identification 8.1 Motor Parameter Self-identification When the vector control mode is selected, the motor parameters must be self-identified. For non-vector control, it is recommended to perform parameter self-identification during the first run in order to improve the control accuracy. users. The EM730/EM730E series inverter has the function of motor parameter The motor parameters required for calculation in vector control are usually not available to self-identification.

When the self-identification is enabled, the inverter will automatically test 298 F27.29 Judgment time for valid cable signal 0.1 - 20.0 s 2.0 ● Function Function code Default Parameter description Unit Attribute code name setting F27.30 Filtering time for material cutoff detection 1 - 100 ms 5 ● Function Function code Default Parameter description Unit Attribute code name setting F27.36 Current value of feedforward gain -500.0~500.0 % ×