sinee — EM730 User Manual

User Manual of EM730/EM730E Series Inverter most requirements.  In order to ensure the control performance, the power of the motor should match with that of the inverter, or the former should be one level lower than the latter under normal circumstances.  After the normal self-identification of motor parameters, the set values of F01.09 to F01.13 and F01.19 to F01.22 will be updated and automatically saved.  When F12.14=1 is restored to the default setting, the values of the function codes F01.00 to F01.13 and F01.19 to F01.22 remain unchanged. 8.3 Self-identification Steps  Set F00.02=0 in the parameter setting status and disconnect the motor from the load.

 According to the motor nameplate parameters, set F01.00 (motor type), F01.01 (rated power of the motor), F01.02 (rated voltage of the motor), F01.03 (rated current of the motor), F01.04 (rated frequency of the motor), F01.05 (rated speed of the motor), F01.06 (winding connection of the motor) and F01.07 (rated power factor of the motor), respectively.  For the asynchronous motor: Set F01.34=1 and press . The inverter will start the static self-identification of the motor. Or, set F01.34=2 and press self-identification of the motor. . The inverter will start the rotary  For the synchronous motor: Set F01.34=11 and press .

The inverter will start the static self-identification of the motor. Or, set F01.34=12 and press . The inverter will start the rotary  It takes about two minutes to complete the self-identification of the motor. Then the system self-identification of the motor. will return to the initial power-on status.  During the self-identification, if you press the STOP/RESET key , “ E24 ” (parameter identification abnormality) will be displayed; and if you press the STOP/RESET key , the system will return to the parameter setting status. If the self-identification fails, “ E24 ” (parameter identification abnormality) will be displayed.

If the STOP/RESET key is pressed , the system will return to the parameter setting status. 300