User Manual of EM730/EM730E Series Inverter 67 (percentage) 7: main frequency communication setting (direct frequency) 8: digital potentiometer setting F00.05 Options of auxiliary frequency source B 0: digital frequency setting F00.07 1:AI1 2:AI2 3: retention 4: retention 5: high frequency pulse input (X5) 6: auxiliary frequency communication setting (percentage) 7: auxiliary frequency communication setting (direct frequency) 8: digital potentiometer setting 9: retention 10: process PID 11: simple PLC 0 〇 F00.06 Options of frequency source 0: main frequency source A 1: auxiliary frequency source B 2: main and auxiliary operation results 3:
switching between main frequency source A and auxiliary frequency source B 4: switching between main frequency source A and main and auxiliary operation results 5: switching between auxiliary frequency source B and main and auxiliary operation results 6: Auxiliary frequency source B + feedforward calculation (winding application) 0 〇 F00.07 Digital frequency setting 0.00 to maximum frequency F00.16 Hz 50.00 ● F00.08 Options of main and auxiliary operation 0: main frequency source A + auxiliary frequency source B 1: main frequency source A - auxiliary frequency source B 2: larger value of main and auxiliary frequency sources 3:
smaller value of main and auxiliary frequency sources 0 〇 F00.09 Reference options of auxiliary frequency source B in main and auxiliary operation 0: relative to he maximum frequency 1: Relative to main frequency source A 0 〇 F00.10 Gain of main frequency source 0.0~300.0 % 100.0 ● F00.11 Gain of auxiliary frequency source 0.0~300.0 % 100.0 ●