User’s Guide for EM760 series high-performance vector inverter 55 double-brush PWM switch control 1: Double-brush 2: Automatic switch F01 Parameter group of motor 1 F01.00 Motor type 0: ordinary asynchronous motor 1: variable-frequency asynchronous motor 2: permanent magnet synchronous motor 0 F01.01 Rated power of electric motor 0.10~650.00 kW Depending on the motor type F01.02 Rated voltage of motor 50~2000 V Depending on the motor type F01.03 Rated current of motor 0.01 to 600.00 (rated power of motor: ≤ 75 kW) 0.1 to 6000.0 (rated power of motor:
> 75 kW) A Depending on the motor type F01.04 Rated frequency of motor 0.01~600.00 Hz Depending on the motor type F01.05 Rated speed 1~60000 rpm Depending on the motor type F01.06 Motor winding connection 0: Y 1: Δ Depending on the motor type F01.07 Rated power factor of motor 0.600~1.000 Depending on the motor type F01.08 Motor efficiency 30.0~100.0 % Depending on the motor type F01.09 Stator resistance of asynchronous motor 1-60000 (rated power of motor: ≤75kW) 0.1 to 6000.0 (rated power of motor: > 75 kW) mΩ Depending on the motor type F01.10 Rotor resistance of asynchronous motor 1-60000 (rated power of motor: ≤75kW) 0.1 to 6000.0 (rated power of motor:
> 75 kW) mΩ Depending on the motor type F01.11 Leakage inductance of asynchronous motor 0.01 to 600.00 (rated power of motor: ≤ 75 kW) 0.001 to 60.000 (rated power of motor: > 75 kW) mH Depending on the motor type F01.12 Mutual inductance of asynchronous motor 0.1 to 6000.0 (rated power of motor: ≤ 75 kW) 0.01 to 600.00 (rated power of motor: > 75 kW) mH Depending on the motor type F01.13 No-load excitation current of asynchronous motor 0.01 to 600.00 (rated power of motor: ≤ 75 kW) 0.1 to 6000.0 (rated power of motor: > 75 kW) A Depending on the