sinee — EM760 User Manual

User’s Guide for EM760 series high-performance vector inverter 57 F01.32 Detection time of speed feedback disconnection 0.0~10.0 (0.0: inactive detection of speed feedback disconnection) 1.0  F01.33 Speed feedback filtering time 0.000~0.100 s 0.002  F01.34 Motor parameter self-learning 0: No operation 1: static self-learning of asynchronous motor 2: rotation self-learning of asynchronous motor 3: Self-learning of asynchronous motor encoder 11: static self-learning of synchronous motor 12: rotary self-learning of synchronous motor 13: encoder self-learning of synchronous motor 0  F02 Input terminal function group F02.00 Options of X1 digital input function 0: no function 1:

terminal running (RUN) 2: running direction (F/R) 3: stop control in three-line operation 4: forward jog (FJOG) 5: reverse jog (RJOG) 6: terminal UP 7: terminal DOWN 8: clear UP/DOWN offset 9: free stop 10: reset fault 11: multi-segment speed terminal 1 12: multi-segment speed terminal 2 13: multi-segment speed terminal 3 14: multi-segment speed terminal 4 15: multi-segment PID terminal 1 16: multi-segment PID terminal 2 17: multi-segment torque terminal 1 18: multi-segment torque terminal 2 19: acceleration and deceleration time terminal 1 20:

acceleration and deceleration time terminal 2 1  F02.01 Options of X2 digital input function 2  F02.02 Options of X3 digital input function 11  F02.03 Options of X4 digital input function 12  F02.04 Options of X5 digital input function 13  F02.05 Options of X6 digital input function 14  F02.06 Options of X7 digital input function 10  F02.07 Options of AI1 digital input function 0  F02.08 Options of AI2 digital input function 0  F02.09 Options of AI3 digital input function 0  F02.10 Options of AI4 digital input function (expansion card) 0  F02.11 Options of X8 digital input function (expansion card) 0  F02.12 Options of X9 digital input function (expansion card) 0  F02.13 Options of X10 digital input function (expansion card) 0  F02.14 Reserved 0 × 21:

Acceleration and deceleration prohibition 22: operation pause 23: external fault input 34: counter input (≤250Hz) 35: high-speed count input (≤100kHz, only valid for X7) 36: count clearing 51: switching of main frequency source to digital frequency setting 52: switching of main