User’s Guide for EM760 series high-performance vector inverter 57 F01.32 Detection time of speed feedback disconnection 0.0~10.0 (0.0: inactive detection of speed feedback disconnection) 1.0 F01.33 Speed feedback filtering time 0.000~0.100 s 0.002 F01.34 Motor parameter self-learning 0: No operation 1: static self-learning of asynchronous motor 2: rotation self-learning of asynchronous motor 3: Self-learning of asynchronous motor encoder 11: static self-learning of synchronous motor 12: rotary self-learning of synchronous motor 13: encoder self-learning of synchronous motor 0 F02 Input terminal function group F02.00 Options of X1 digital input function 0: no function 1:
terminal running (RUN) 2: running direction (F/R) 3: stop control in three-line operation 4: forward jog (FJOG) 5: reverse jog (RJOG) 6: terminal UP 7: terminal DOWN 8: clear UP/DOWN offset 9: free stop 10: reset fault 11: multi-segment speed terminal 1 12: multi-segment speed terminal 2 13: multi-segment speed terminal 3 14: multi-segment speed terminal 4 15: multi-segment PID terminal 1 16: multi-segment PID terminal 2 17: multi-segment torque terminal 1 18: multi-segment torque terminal 2 19: acceleration and deceleration time terminal 1 20:
acceleration and deceleration time terminal 2 1 F02.01 Options of X2 digital input function 2 F02.02 Options of X3 digital input function 11 F02.03 Options of X4 digital input function 12 F02.04 Options of X5 digital input function 13 F02.05 Options of X6 digital input function 14 F02.06 Options of X7 digital input function 10 F02.07 Options of AI1 digital input function 0 F02.08 Options of AI2 digital input function 0 F02.09 Options of AI3 digital input function 0 F02.10 Options of AI4 digital input function (expansion card) 0 F02.11 Options of X8 digital input function (expansion card) 0 F02.12 Options of X9 digital input function (expansion card) 0 F02.13 Options of X10 digital input function (expansion card) 0 F02.14 Reserved 0 × 21:
Acceleration and deceleration prohibition 22: operation pause 23: external fault input 34: counter input (≤250Hz) 35: high-speed count input (≤100kHz, only valid for X7) 36: count clearing 51: switching of main frequency source to digital frequency setting 52: switching of main