User’s Guide for EM760 series high-performance vector inverter 59 F02.28 Maximum input pulse frequency 0.01~100.00 kHz 50.00 ● F02.29 Maximum input setting –100.0~+100.0 % 100.0 ● F02.30 Pulse input filtering time 0.00~10.00 s 0.10 ● F02.31 Options of analog input function Ones place: AI1 0: analog input 1: digital input (0 below 1V, 1 above 3V, the same as last time under 1-3V) Tens place: AI2; as above Hundreds place: AI3; as above Thousands place: AI4 (expansion card); as above 0000D F02.32 Options of analog input curve Ones place: Options of AI1 curve 0: curve 1 1: curve 2 2: curve 3 3: curve 4 Tens place: AI2 curve selection; as above Hundreds place:
AI3 curve selection; as above Thousands place:
AI4 curve selection; as above 3210D F02.33 Minimum input of curve 1 0.00~F02.35 V 0.10 ● F02.34 Minimum input setting of curve 1 –100.0~+100.0 % 0.0 ● F02.35 Maximum input of curve 1 F02.33~10.00 V 9.90 ● F02.36 Maximum input setting of curve 1 –100.0~+100.0 % 100.0 ● F02.37 Minimum input of curve 2 -10.00~F02.39 V 0.10 ● F02.38 Minimum input setting of curve 2 –100.0~+100.0 % 0.0 ● F02.39 Maximum input of curve 2 F02.37~10.00 V 9.90 ● F02.40 Maximum input setting of curve 2 –100.0~+100.0 % 100.0 ● F02.41 Minimum input of curve 3 0.00V~F02.43 V 0.10 ● F02.42 Minimum input setting of curve 3 –100.0~+100.0 % 0.0 ● F02.43 Input of inflection point 1 of curve 3 F02.41~F02.45 V 2.50 ● F02.44 Input setting of inflection point 1 of curve 3 –100.0~+100.0 % 25.0 ● F02.45 Input of inflection point 2 of curve 3 F02.43~F02.47 V 7.50 ● F02.46 Input setting of inflection point 2 of curve 3 –100.0~+100.0 % 75.0 ●