User’s Guide for EM760 series high-performance vector inverter 71 failure 0: allow retry after failure 1: disable retry after failure F07.19 Action option 1 after failure E21 E16 E15 E14 E13 E12 E08 E07 00000000 0: free stop 1: stop according to stop mode F07.20 Action option 2 after failure E28 E27 E25 E23 0000 0: free stop 1: stop according to stop mode F07.21 Options of load loss protection 0: Invalid 1: valid 0 ● F07.22 Load loss detection level 0.0~100.0 % 20.0 ● F07.23 Load loss detection time 0.0~60.0 s 1.0 ● F07.24 Options of load loss protection action 0: free stop 1: stop according to stop mode 1 F07.25 Motor overspeed detection level 0.0-50.0 (reference:
maximum frequency F00.16) % 20.0 ● F07.26 Motor overspeed detection time 0.0-60.0, 0.0: disable motor overspeed protection s 1.0 ● F07.27 AVR function 0: Invalid 1: valid % 1 F07.28 Stall fault detection time 0.0-6000.0 (0.0: no stall fault detection) s 0.0 F07.29 Stall control intensity 0~100 % 20 F07.30 Instantaneous stop/no-stop deceleration time 0.00~300.00 S 20.00 F07.32 Options of retries after failure 2 E10 E13 E15 E16 * E19 E20 * 11111111 0: allow retry after failure 1: disable retry after failure F07.34 Encoder disconnection detection percentage 0~150.0 % 100.0 F07.35 Protection shield 2 * * * * * * E18 E81 00 0: valid protection 1:
shielded protection F07.36 Options of retries after failure 3 * * * * * * E09 E17 11 0: allow retry after failure 1: disable retry after failure F07.37 Initial voltage for saving upon power disconnection 60.0~F07.38 % 76.0 F07.38 Electrification voltage reading and determination F07.37~100.0 % 86.0 F07.39 Delay time of electrification reading and determination 0~100.0 S 5.00 F07.40 Delay time of steady undervoltage determination 50~6000 ms 20 F07.41 Selection of input phase loss 0: Software detection 0