US Army Materiel Command AMCP 706-197 — AMCP 706-197 Reliability Prediction Handbook — US Army Engineering Design Guide PDF

Downloaded from https://www.everyspec.com AMCP 706-197 TABLE 13-2 ASSIGNMENT OF P NAMES TO SIMPLE CIRCUIT MODEL 1 ELEMENT NAME P NAME EVENT BATTRY PVOLT battery delivers proper voltage SHORT PSTG short to ground does not occur at this point START PCLOS switch closes when pressure applied - 00FF switch remains open before pressure is applied COIL PPICK symbolizes the event that coil pIcks contact when proper input is applied CONTCT PC0NT contacts provide continuity when picked OERLY contacts remain open before relay is picked LIGHT PLITE light burns when proper voltage applied FUSE POPEN squib open when proper input applied SQUIB PBLOW squib fires when proper voltage is applied WIRE PGOOD wire carries signal applied 13-4