US Army Materiel Command AMCP 706-197 — AMCP 706-197 Reliability Prediction Handbook — US Army Engineering Design Guide PDF

Downloaded from https://www.everyspec.com )BLOCK C * AMCP 706-197 [' BLOCK 8 BLOCK A C- B 0C ___ Ca 1out-of-3: G 3-out-of-7: G 1 repairman: strategy is defined in the text. System is Good (up) if and only if A,B,C, are Good (up). FIGURE 6.23. System For Example No. 1 placement; the kind shown separtely in Fig. a. A unit from a blo.k that is down. 6-23 are more difficult to replace. If more than one block is down, it makes no The system consists of three blocks:' difference which is chosen. 1. Block A is a 1-out-of-l:G-subsystem. b. An easily-replaceable spare. If 2. Block B is a 1-out-of-3:G-subsystem. more than one block is down, choose the one 3.

Block C is a 3 out-of-7:G-subsystem, from the block that has the fewest spares that are good. The system is up if and only if Blocks A, 3. If a rule is not given completely B, C are Good (up). enoigh, choose one from the allowable failed The optimum repa ; v et.ategy can only be units at random. determined by choosing a figure-of-merit to The rules can become quite complicated optimize, and then solving the problem. A in a theoretical analysis. In practice, the re- reasonable set of priorities (in the absence of pairman should not be required to make corn- the complete solution) for the repairman plicated calculations merely to find out which might be the following: unit to work on.

The rules also can be so 1. Finish replacing the unit being worked complicated as to make theoretical analysis on, if any virtually impossible. If the replacement rate is 2. If more than 1 unit is failed, choose, much higher than the failure rate, the stand- in the following order, the one to be replaced: ard matrix techniques can be used. 6-33