Epson L-6034VW Operation Guide Touch Panel Basic Operations Note: ❏ When there are multiple selection items for Print Mode , compare the following image checkpoints and select the best quality. ❏ Spot color uniformity between head bands ❏ Head splice quality (variations in glossiness or between shades of color) ❏ Enable corona treatment if print quality declines. 112 Item Explanation Additional UV Lamp Curing Unit Strength Set the strength of the UV emitted from the additional UV lamp curing unit within a range of 27 to 100%. Enabled when Additional UV Lamp Curing is set to Apply. Default value:
50% However, if you select Film #1 or Film #2 as the Print Mode and perform the following low speed printing, the UV light strength during operation is 27 to 50%. ❏ Variable printing ❏ Banner Printing ❏ White plate printing for reverse white printing ❏ Set Print Speed to Low speed in the preset Corona Treatment Set when using a corona treater. Corona treatment can improve spreading of ink. Do Not Apply A corona treater is not used. Select Do Not Apply for paper or foil paper substrates. Apply A corona treater is used to process the surface of the sub- strate so that ink can be easily fixated. Using the Ionizer Set when using an ionizer.
Yes Uses the ionizer to remove static electricity from the sub- strate. Adjust the ion balance while printing. We recommend selecting this when the following Sub- strate Type is set. ❏ Printing side: Paper / Reverse side: Film ❏ Printing side: Film / Reverse side: Paper ❏ Printing side: Film / Reverse side: Film ❏ Film No Does not use the ionizer. We recommend selecting this when the following Sub- strate Type is set. ❏ Printing side: Paper / Reverse side: Paper ❏ Paper