EPSON — When do I need to change the tension settings?

Epson L-6034VW Operation Guide FAQ ❏ Change the preset for printing From the Print Settings / Reprint Settings screen, select a preset that differs from the preset currently being used To access the Print Settings / Reprint Settings Screens Select the print job from the Job Management menu - Waiting or Pause tab, and then press Print Settings Select the print job from the Job Management menu - Printed tab, and then press Reprint (only when selecting individual jobs) Note: ❏ When the settings for the default preset are changed under the following conditions, the latest settings are automatically applied to the print job.

❏ Use the default preset ❏ When Do not Fix until Printing is set in Fixing Default Preset ❏ When re-printing a job that has already been printed, the preset saves the settings from the last time printing was performed. If you have changed the preset settings after printing, press Apply Preset to update the settings and then re-print. When do I need to change the tension settings? A. Change the tension if it does not match the value for the loaded substrate. When the tension value that is set does not match the loaded substrate, substrate feeding is not stable, and wrinkles, tension errors, and telescoping may occur for the substrate.

When you select Substrate Type , the standard tension value is applied; see the following tables to change the tension value if any problems occur. 229 Problem What to do Telescoping occurs in the unwinder roll Lower the tension value for unwinding by 0.7 times the standard value. * Film that is 250 mm or wider wrinkles easily. We recommend setting 15 N or more. Telescoping occurs when rewinding the roll too quickly When telescoping of 10 mm or more occurs, lower the tension value for rewinding by 0.7 times the standard value. Telescoping occurs when rewinding the roll too slowly ❏ Increase the tension value for rewinding by 1.3 times the standard value.

❏ Since telescoping occurs easily in film that is 120 mm or narrower, be careful when removing from the rewinder axis. "Foreign substance detected on substrate path channel" is displayed on the error screen If there are wrinkles or creases in the substrate on the substrate path channel when unwinding, increase the tension value for unwinding by 1.3 times the standard value. Additionally, replace the paper core and wind the substrate. "Tension in the unwinder side has fallen below the minimum value." is displayed on the error screen See the following to raise the tension value for unwinding. ❏ When the value is below the standard value:

Return to the standard value ❏ When the value is higher than the standard value: Increase by 5 N more than the current value "Tension in the rewinder side has fallen below the minimum value." is displayed on the error screen See the following to raise the tension value for rewinding. ❏ When the value is below the standard value: Return to the standard value ❏ When the value is higher than the standard value: Increase by 5 N more than the current value