EPSON — ^GF

 Graphic data is handled as follows.  If the data format is binary, you can use any binary data as Parameter data. At this time, the size of Parameter data must be matched to the size specified in Parameter t.  If the data format is a hexadecimal character string, one character from 1. to 3. below is used as Parameter data. At this time, the size of Parameter data written in binary must be matched to the size specified in Parameter t. 1. 0 to 9, A to F, and a to f in ASCII can be used as hexadecimal graphic data. 2. ASCII comma , the parameter separator character, is used to separate lines.

If a comma is input, processing is carried out as if ASCII 0 was input for the remainder of the line. 3. G to Y and g to z in ASCII can be used as repetition characters. For example, if I9 is input, processing is carried out as if 999 were input. The following table indicates the number of repetitions. [Response] None [Reference] Related commands: None ESC/Label Command Reference Guide Rev.

L Page 131 Character Specified times Character Specified times Character Specified times Character Specified times G 1 Q 11 h 40 r 240 H 2 R 12 i 60 s 260 I 3 S 13 j 80 t 280 J 4 T 14 k 100 u 300 K 5 U 15 l 120 v 320 L 6 V 16 m 140 w 340 M 7 W 7 n 160 x 360 N 8 X 18 o 180 y 380 O 9 Y 19 p 200 z 400 P 10 g 20 q 220