EPSON — ^BU

^BU [Name] UPC-A barcode [Format] ^BU o ,h ,i ,a ,c [Function]  Set the UPC-A barcode to the current field.  Sets the field orientation based on Parameter o.  Sets the barcode height based on Parameter h.  Sets the HRI character printing based on Parameter i.  Sets whether to position the added HRI characters on the top or on the bottom of the barcode based on Parameter a.  Sets the check digit printing based on Parameter c. [Encoding]  Numerals (0 to 9) can be encoded.  11 characters can be encoded.  The check digit is added automatically. The check digit is calculated by modulus 10 / 3 weight.

 The first character is treated as the number system character when encoding the specified field data. [Response] None [Reference] Related commands: ^FW , ^BY ESC/Label Command Reference Guide Rev. L Page 80 Parameters Description Definition range o UPC-A field orientation o = N/R/I/B N: Normal R: 90° rotation (clockwise) I: 180° rotation B: 270° rotation (clockwise) h UPC-A barcode height [dot] 1 ≤ h ≤ 32000 (Varies depending on the model) i Set/cancel of HRI character addition for UPC-A i = Y/N Y: Set N: Cancel a Set/cancel of HRI character addition for top of UPC-A barcode a = Y/N Y: Set N: Cancel c Set/cancel check digit printing for UPC-A c = Y/N Y: Set N: Cancel