EPSON — ^BX

^BX [Name] Data Matrix [Format] ^BX o ,s ,e ,c ,r ,d ,i ,f [Function]  Sets the Data Matrix symbol to the field.  Sets the field orientation based on Parameter o.  Sets the size of each module comprising the symbol based on Parameter s.  Sets the symbol’s error correction level based on Parameter e. ESC/Label Command Reference Guide Rev. L Page 81 Parameters Description Definition range o Data Matrix field orientation o = N/R/I/B N: Normal R: 90° rotation (clockwise) I: 180° rotation B: 270° rotation (clockwise) s Data Matrix module size 1 ≤ s ≤ 32000 (Varies depending on the model) e Data Matrix error correction level e = 0/50/80/100/140/200 0: ECC000 50: ECC050 80: ECC080 100:

ECC100 140: ECC140 200: ECC200 c Data Matrix column count 9 ≤ c ≤ 49 If e = 200, then 10 ≤ c ≤ 144 r Data Matrix line count 9 ≤ r ≤ 49 If e = 200, then 8 ≤ r ≤ 144 d Data Matrix data type d = 1/2/3/4/5/6 1: Numerals and blank characters 2: Capital letters of the alphabet (A to Z) and blank characters 3: Numerals, capital letters of the alphabet (A to Z), blank characters, periods , commas , dashes , and slashes . 4: Numerals, capital letters of the alphabet (A to Z), and blank characters 5: ASCII code (00H to 7EH) 6: ASCII code (00H to FFH) i Data Matrix ECC200 escape sequence identifier Any ASCII single character f Data Matrix ECC200 symbol shape f = 1/2 1: Square 2: Rectangle