Iveco — EuroCargo E4 BODYBUILDER INSTRUCTIONS

SPECIFIC INFORMATION AND INSTRUCTIONS 5-12 E URO C ARGO E URO 4 - 5 ”Allison” 12-pin connector for RSU vehicle (Urban Solid Waste), optional (grey color): ST77 Spare part Order number for male-holding coupling: 41118329 Spare part Order number for female-holding coupling: 41118310 Table 5.9 - 12 pin connector ST77 ”Allison” 12-pin connector for Fire Fighting vehicles, optional (grey color): ST77 Spare part Order number for male-holding coupling: 41118329 Spare part Order number for female-holding coupling: 41118310 Table 5.10 - 12 pin connector ST77 Bodybuilder connectors Base - July 2006 Revi - June 2007 Print 603.93.431 Pin Description Connections Remarks Type Wire code Max.

load 1 Idle indicator for Extra PTO OUT high side 145 0.5 A Idle gearbox: ground for idle engaged 2 Switch on RSU IN 123 15 mA 1st gear limitation and reserve gear inhibition open circuit = function engaged closed on line at 24V = function not engaged 3 Not enabled 142 4 PTO enabled IN 143 15 mA Input for PTO switch open circuit = PTO not required closed on 24 V line = PTO required 5 PTO command OUT high side 130 0.5 A PTO enabled: +24V output for valve solenoid 6 Reserved 7 Reserved 8 Double input for automatic idle IN 117 5 mA Automatic transmission idling.

Control logics ”and” with pin 9 open circuit = function not engaged closed on digital ground = function engaged 9 Double input for automatic idle IN 101 5 mA Automatic transmission idling. Control logics ”and” with pin 8 open circuit = function not engaged closed on digital ground = function engaged 10 Digital ground POWER 103 Digital ground. To be used as return for inputs ”closed on digital ground”. Do not connect to the negative battery or to other grounds. 11 Interval indicator OUT low side 113 0.5 A Transmission: ground for idle not engaged. 12 Reserved Pin Description Connections Remarks Type Wire code Max. load 1 Idle indicator for Extra PTO OUT high side 145 0.5 A Idle transmission:

Ground for idle engaged 2 Not enabled 123 3 Aux function interval disabled IN 142 5 mA Transmission idling. Control logics ”and” with pin 9 open circuit = function not engaged closed on digital ground = function engaged 4 PTO enable IN 143 15 mA Input with PTO switch open circuit = PTO not required closed on 24V line = PTO required 5 PTO command OUT high side 130 0.5 A +24V output to engage PTO by means of valve solenoid. 6 Reserved 7 Reserved 8 Not enabled 117 9 Aux function interval enabled IN 101 5 mA Control logics ”and” with pin 3 open circuit = function not engaged closed on digital ground = function engaged 10 Digital ground POWER 103 Digital ground.

To be used as return for inputs ”closed on digital ground”. Do not connect to the negative battery or to other grounds. 11 Level indicator OUT low side 113 0.5 A Transmission: ground for idle not engaged. 12 Reserved