Iveco — EuroCargo E4 BODYBUILDER INSTRUCTIONS

CHASSIS MODIFICATIONS 2-79 E URO C ARGO E URO 4 - 5 Their insertion into the vehicle’s circuits must include a separate recharging system (see Figure 2.32) integrated with that of the vehicle. In this case it is advisable to provide supplementary batteries with the same capacity as the batteries originally installed in order to ensure correct recharging of all batteries. Figure 2.32 Fitting of additional batteries 91508 1 Standard batteries 2 Supplementary batteries 3 Alternator with built-in regulator 4 Starter motor 5 Starter key 6 Relays 7 Battery charging condition tell-tale Installing additional batteries involves checking that the alternator is of a sufficient capacity to recharge.

If necessary, an alternator with larger power or an additional one must be used. In this case connect up as shown in Figure 2.33. When using electric motors which are activated only while the vehicle engine is running, instead of supplementary batteries, it could be sufficient to use a larger power alternator or a supplementary one. Such alternators have to be equipped with Zener diode rectifiers in order to avoid damaging the electrical/electronic systems already fitted which might arise from accidental disconnection of the batteries. Also, every alternator must have a warning light to signal when the battery is not recharging.

Operations on the electrical system Print 603.93.431 Base - July 2006 Revi - June 2007