CHASSIS MODIFICATIONS 2-82 E URO C ARGO E URO 4 - 5 a) Batteries The different types of available batteries are given in the table below. Table 2.20 (1) not available for mechanical susp. 3105 wheelbase. Figure 2.35 116423 POSITIVE CONNECTION CENTRAL UNIT (CBA) M1. Supply from thru connector + or IGC / TGC - M2. Supply output to starter motor - M3. Output to relay Grid Heater - M4. Fuse box supply output - M5. Special outfit supply output Take the power through the special terminal C provided for this purpose; on the terminal board there is a special pole for the bodybuilders. With engine stopped: Up to 10% of the battery rating. With engine running:
A further 20% of the battery rating can be drawn, according to the alternator power and the engine revs When greater power is needed, uprated batteries and alternator should be fitted for frequent use with high loads (E.G. tail lifts) higher capacity batteries (minimum 110A) with an alternator of not less than 90A should be fitted. Additional circuits should be isolated and protected with suitable fuses, positioned near to the current drawing point, as specified in the Table 2.18. Protect the additional cables by means of special sheaths or corrugated covers, and install them in compliance with the instruction of 2.21. ! NOTE : On the ML120E..
P ML190ELmodels with automatic transmission , the only available (standard) alternator is 90A type. Operations on the electrical system Base - July 2006 Revi - June 2007 Print 603.93.431 Batteries Alternator Model 70 Ah 88 Ah 110 Ah 143 Ah 170 Ah 70 A 90 A 60 - 80EL standard - opt 567 opt 568 (1 ) - 80 - 120 EL - - standard opt 568 (1 ) - 120 -190 - - standard opt 568 opt 5031 standard opt 6315 100W - 140W - - standard opt 568 opt 5031