Department of Defense MIL-HDBK-816 Notice 1 — MIL-HDBK-816 Notice 1 Radiation Hardness Assurance Guidelines Manual PDF

Downloaded from https://www.everyspec.com MIL-HDBK-816 NOTICE 1 for the majority of the parts; the presence of such parts cannot be detected with confidence by the sample sizes which are typical of radiation tests. At the 6-nines level also, human errors in making measurements or in handling the parts can become a significant failure mode which is totally outside the assumed causes of part failure. Perform Pre-Rad Measurement. Measure Device Characteristics Perform Irradiations. Perform Post-Rad Measurements. Record and Document Pre-Rad and Post-Radiation Data. Select Desired Lot Acceptance Probability and Confidence Levels for Sample Size Series Tests.

Calculate RHA End Point Limits (RHEPL) Select RHA Sample Size Series Test Requirements. Calculate RHEPL From Characterization Data. Incorporate the RHEPL Values and Sample Size Series Test Requirements into the Detailed Specifications. Coordinate Detailed RHA Specification. Incorporate RHEPL and Publish the Detailed RHA Specification. FIGURE 2 Flow diagram for characterizing and specifying the performance of semiconductor devices in a radiation environment. 4.4 Part characterization. Figure 2 shows the major steps by which characterization data is measured and used for calculating the RHEPL which are then used in the device procurement specification for radiation qualification and LAT.

An important point shown on figure 2 is that an objective must be selected for the LAT (or QCI) tests and that the RHEPL are then calculated to meet that objective (the acronym PIPL, standing for post-irradiation parameter limits, is also used). Thus, for example, the objective could be to set the end-point limits so that, with 90 percent confidence, at least 90 percent of future lots may be expected to pass a 22/0 test. Pre-rad measurements are essential when the change (delta) in the value of a parameter is of greater interest than the absolute value of the parameter. Although they may not be essential when the SUPERSEDES PAGE 12 OF MIL-HDBK-816 12