Downloaded from https://www.everyspec.com MIL-HDBK-816 NOTICE 1 5.2.4.4.5.2 Steps in multi-lot analysis. The following steps are then used in the calculation: a. Let the number of lots be N and the number of devices in each lot be n I . For the Ith lot, calculate the mean value and the standard deviation of the given parameter. Specifically, for the Ith lot, the quantities calculated are MEAN I (PAR (RAD)) and STDEV I (PAR (RAD)) as given by the following equations:

1 n I MEAN I [PAR (RAD)] = n I Σ PAR Ij (RAD) j = 1 where PAR Ij (RAD) is the measured value of PAR(RAD) for the jth device in the Ith lot, and STDEV [PAR (RAD)] = 1 n I [ n I -1 Σ [PAR Ij (RAD) – MEAN I PAR (RAD)] 2 ] 1/2 j = 1 b. For each lot multiply the standard deviation by 2.326 (see explanation below) and add it to the mean (addition is used for a parameter that increases in value with increasing radiation level). This gives a limit: LIM I = MEAN I (PAR (RAD)) + 2.326 x STDEV I (PAR (RAD)) for the Ith lot. c. For the N values of LIM I , obtain the MEAN(LIM) and the standard deviation STDEV(LIM). d.

Look up the one-sided-tolerance-limit factor K TL for 90 percent probability and 90 percent confidence and for a sample size corresponding to N, the number of lots. e. Use the following equation to obtain the desired RHEPL: RHEPL = MEAN(LIM) + K TL (C = .9, P = .9, N) x STDEV(LIM) 5.2.4.4.5.3 The rationale of the method given above. The rationale of the method given above is to examine the distribution of the 99 percentile points of the different lots and treat them as a normal (or lognormal) distribution.

For each lot, adding MEAN(PAR) + 2.326 x STDEV(PAR) gives the best estimate of the 99 percentile point because, for a standard normal distribution, 2.326 standard deviations above the mean includes 99 percent of the distribution. The K TL factor in step D above then is used to obtain an estimate that, with 90 percent confidence, 90 percent of the lots will have 99 percent of their parts within the calculated RHEPL. 5.2.4.4.5.4 An illustrative example of an RHEPL calculation for case 2. The following example was taken from actual data on voltage shifts (deltas) measured after an ionizing radiation dose of 400 kRad.

(This data is interesting for other reasons as well and, for those reasons, will be discussed in greater detail in appendix II.) The lots do not all have five parts per lot, but the within-lot standard deviations are so small compared to the lot-to-lot variations that the case 2 method can still be used. The data in this example is treated as a normal distribution (instead of a lognormal distribution). The values shown in table XIV yield the values shown in table XVI. SUPERSEDES PAGE 35 OF MIL-HDBK-816 35