Department of Defense MIL-HDBK-816 Notice 1 — MIL-HDBK-816 Notice 1 Radiation Hardness Assurance Guidelines Manual PDF

Downloaded from https://www.everyspec.com MIL-HDBK-816 NOTICE 1 1. SCOPE 1.1 Scope. The primary objective of this document is to provide guidelines and easy to follow procedures for the preparation of detailed device specifications for the procurement of microcircuits and semiconductor devices where radiation Hardness Assurance (RHA) is required.

The guidelines are applicable to MIL-M-38510, MIL-PRF-38534, MIL-PRF-38535, and MIL-PRF-19500 microcircuit and semiconductor device detailed specifications, Standard Microcircuit Drawings (SMDs) as well as other contractor prepared specifications such as Source Control Drawings (SOCD), Selected Item Drawings (SID), and Specification Control Drawings (SCD). Recommended procedures are provided for characterizing the radiation response of a part and for obtaining post-irradiation post-irradiation end-point limits for qualification and Lot Acceptance Tests (LAT). 1.2 Radiation hardness assurance at the piece part level.

These guidelines address radiation response measurement and hardness assurance questions at the piece part level. In keeping with the present scheme for military standard RHA device specifications, which only addresses ionizing radiation dose effects measured at 50 to 300 rads(Si)/second (see table I), these guidelines emphasize that radiation environment. However, because the addition of dose rate and Single Event Upset (SEU) specifications is now under consideration, brief mention of these two radiation events is also included.

The principles discussed are applicable to both bipolar and MOS silicon transistors and integrated circuits, and to devices made from gallium arsenide and other semiconductor materials. They have, furthermore, been presented in terms of the intrinsic performance characteristics of the part independent of any system in which it may be used. For military standard specifications, the levels shown in table I are used as reference points. The general principles may be applied to system specific requirements. 1.3 LAT end-point limits.

The procedure for measuring radiation response characteristics and for calculating LAT end- point limits are discussed in terms of parts whose design and production processes are mature and stable. That is, these guidelines do not attempt to discuss the case where the part is still under development or is not under change control, and hence its characteristics are subject to change. It is recognized that this latter case is important and occurs frequently because system designers are interested in obtaining the most advanced parts for their systems.

The process of obtaining LAT end-point limits for such parts, however, involves testing and iterative end-point adjustments by the part manufacturer and the system parts engineers and designers which would be difficult to formulate as a set of generalized steps which could be applied to a variety of system needs. Because military standard procurements of RHA devices use attribute sample size series LAT tests (see Appendix D of MIL-PRF-38535), the end-point limit discussions here emphasize sample size series tests. 1.4 Low yield devices. If sample costs are affordable, the LAT methods discussed will be performed on samples of the devices themselves.

In the case of Very Large Scale Integration (VLSI) devices, one possible option might be to use devices for LAT which are acceptable from an electrical performance standpoint but do not meet all the normal visual acceptance criteria. Such devices are said to be selected according to “alternate” visual criteria. Another possible option might be to use test structures for LAT which have been processed on the same wafers as the lot under consideration.

By test structures are meant simpler and less expensive microcircuits which have been designed specifically to correlate with the radiation response characteristics and failure levels of the subject VLSI circuit; radiation tests on the test structure can then be used to estimate the performance characteristics of the VLSI circuit. The use of test structures for LAT cannot be recommended until data and experience show definitively that test structure responses correlate reliably with the actual devices. 1.5 Qualified manufacturers list program.

The qualified manufacturers list (QML) program allows a device manufacturer the flexibility to implement best commercial practices to the maximum extent possible, while still providing product that meets the military performance needs and whose performance is stable. The manufacturing line is controlled through the manufacturer’s quality management (QM) program once the QM program has been certified and qualified. Several levels of product assurance, including radiation hardness assurance (RHA), are provided for. For those devices that will be certified as RHA, the manufacturer must have a technology review board that is cognizant of the factors that affect radiation hardness assurance.

In addition, the manufacturer needs an RHA QM plan that establishes the procedures to be followed to ensure that the devices meet the radiation hardness assured capability level that the manufacturer has selected. The certification requirements for an RHA product include a process capability demonstration, wafer fabrication certification, and a wafer acceptance plan. This topic is discussed in much more detail in MIL-PRF-19500, MIL-PRF-38534, and MIL-PRF- 38535. SUPERSEDES PAGE 1 OF MIL-HDBK-816 1