MIL-HDBK-304C 9.0 CUSHIONING MATERIAL TEST PROCEDURES AND APPARATUS 9.1 Determination of Cushioning Material Characteristics. Design data for the pertinent characteristics of cushioning materials are a prerequisite for rational cushioning design. Generally, this information is obtained by designers, (1) directly from vendors, (2) by conducting their own tests, (3) from published literature, and (4) by deduction from material specification tests. To be useful, test data for design purposes should be collected under environmental conditions approximating the service environment.
Therefore, the practical value of published test data must be assessed by a designer primarily according to their knowledge of the test procedures and apparatus used. Some knowledge about the reliability of the testing facility is also helpful. The information in this chapter is presented to provide the designer with sufficient information about test methods, apparatus, and underlying principles to enable them to conduct their own tests of cushioning characteristics and to assess the applicability and practical value of published design data. 9.1.1 Sample Preparation. The specimens should be the cushioning materials used in the various tests. They should have six rectangular faces.
The length and width of the top and bottom faces usually will be equal and at least four inches long. Height should not exceed width or length of the specimen. 9.1.1.1 Cutting. Care is required in cutting properly sized specimens to ensure flat, smooth, mutually perpendicular, and correctly dimensioned cushion faces. Equipment for cutting the material include band saws, hot wires, and table saws equipped with circular knife edged blades. 9.1.1.2 Checking. Unless otherwise specified, the following material checks should be performed on the specimens. Only test samples passing these checks should be accepted for testing. 9.1.1.2.1 Homogeneity.
Materials should show no visual evidence of non-uniformity in the mixture of their various component ingredients. Cell size should be uniform throughout the sample. Check with the specific foam material specification for exact homogeneity requirements. 9.1.1.2.2 Perpendicular Surfaces. All intersecting specimen faces should be mutually perpendicular to within 2 degrees. 9.1.1.2.3 Parallel Surfaces. All parallel faces should be parallel to within 2 degrees. 9.1.1.2.4 Flatness. All surfaces should be flat to within 1/32 inch (0.75 mm). 9.1.1.2.5 Dimensions. The length and width should be within 1/16 inch (1.5 mm) of nominal.
The height should be within 1/32 inch (0.75 mm) of nominal when measured in accordance with paragraph 9.1.2. 9.1.1.2.6 Density. Material density, when specified, should be within 10 percent of the specified density when measured in accordance with paragraph 9.1.3. 9.1.1.3 Identification. Assign an identification code to each specimen and mark specimens accordingly. 9.1.1.4 Conditioning. Unless otherwise noted in a test specification, specimens should be conditioned to equilibrium in air uniformly maintained at 73є + 4єF (23 + 2єC) and 50 + 2 % relative humidity. Ambient conditions during conditioning should conform to those during testing.
A specimen should be considered at equilibrium when its weight change during a one hour conditioning period does not exceed 0.02 % of its final weight for that period. 70 Downloaded from https://www.everyspec.com