N/A (no manufacturer mentioned) N/A — MIL-HDBK-304C Package Cushioning Design Handbook PDF Download

Downloaded from https://www.everyspec.com MIL-HDBK-304C 9.1.2 Measuring Dimensions. 9.1.2.1 Scope. This procedure is used to determine the overall length, width, and thickness of a cushion specimen. 9.1.2.2 Apparatus. Length will be measured using a jig with one moveable block (Figure 9-1) and a measuring scale graduated to .01 inch (0.3 mm). A plate and dial indicator (Figure 9-2) may be used to measure thickness. The plate should be of suitable size and weight to provide a uniform load of 0.025 (1.75 kg/mmІ) the entire specimen. 9.1.2.3 Conditioning. Test specimens should be conditioned per paragraph 9.1.1.4. 9.1.2.4 Test Procedure.

Length of specimen should be determined in the jig (Figure 9-1). Place the movable block firmly against the end of the specimen and measure the distance between the two blocks at the midpoints of the specimen edges to the nearest 0.01 inch (0.3 mm). Width of the specimen will be determined in like manner. To determine the thickness of the specimen, load the top surface area of the specimen with a flat plate (Figure 9-2) to of 0.025 (175 kg/mmІ), To determine the load in English, use the following example: 4" x 4" x (0.025 psi) = 0.40 pounds force. To determine the load in Metric use the following example: 102mm x 102mm x 1.75 x 10 -5 kg/mmІ = 0.183 kg force.

After a 30 second interval and while the specimen is still under load, either measure the thickness at the geometric center of the specimen's top surface with the dial indicator or average the thickness measurements at the four corners using a scale. 9.1.3 Density. 9.1.3.1 Scope. This procedure is used to determine cushion material density in pounds per cubic foot. 9.1.3.2 Apparatus. The apparatus will be a weighing scale or torsion balance capable of weighing a specimen to within 0.02 % of its weight. 9.1.3.3 Conditioning. Test specimens should be conditioned per paragraph 9.1.1.4. 71