MIL-HDBK-304C 9.1.6 Vibration Transmissibility. 9.1.6.1 Scope. This section covers a method for determining the vibration transmissibility/isolation capability of cushioning materials, especially those that exhibit nonlinear dynamic load-deflection characteristics. The data derived by this method may not necessarily represent the actual performance of these materials in packages. The method of specimen containment, specimen size, and frequency sweep rate can all affect the data. However, the data obtained by this test procedure should provide useful guidance for initial package design. 9.1.6.2 Outline of Method. A test block representing a packaged item is fixtured on a vibration tester.
The signal outputs from transducers located in the test block and on the platform of the vibration tester are fed into a suitable recording system. The recorded test data can then be analyzed and presented in the form of vibration transmissibility-frequency curves. 9.1.6.3 Testing Apparatus. The transmissibility tester should consist of a test block and fixture mounted on the platform of the vibration tester. The test block is a rectangular parallelepiped constructed to facilitate incremental changes in weight. The faces of the test block in contact with the cushion test specimens should measure 8" x 8" (200mm x 200mm).
An accelerometer will be mounted in a cavity located at the geometric center of the test block. The test fixture is designed to restrict the test block to essentially vertical movement with a minimum of friction. A second accelerometer should be attached to the vibration tester platform to monitor its vertical movement. It is important that the test block be free from friction and rotation which would reduce transmissibility and change the frequency at resonance. Also, care must be taken to avoid separation between the test block and the test material during testing to prevent test data distortion.
The existence of a void between the test material and test block can result in shock excited ringing of the test block. 9.1.6.4 Recording Apparatus. A computer controlled data acquisition system provides detailed analysis of data and the direct plotting of transmissibility versus frequency curves. All recording systems, regardless of type (including transducers and recorders) must have a frequency response which is adequate to measure the peak acceleration versus frequency values to an accuracy of + 5 % of the actual value. 9.1.6.5 Test Specimens. Each test specimen will have length and width dimensions of 8 inches (200 mm) unless otherwise specified.
Specimen thickness should be those of particular interest to the investigator or as required in the material specification. Dimensions should be measured according to paragraph 9.1.2. The weight and density of the test specimens should be determined in accordance with paragraph 9.1.3. 9.1.6.6 Conditioning. Test specimens will be conditioned per paragraph 9.1.1.4. 9.1.6.7 Test Procedure. See paragraph 5.5.6 on Transmissibility Curve Development for the test procedure. Use ASTM D 999, Methods of Vibration Testing of Shipping Containers, and ASTM D 4728, Standard Test Method for Random Vibration of Shipping Containers for Vibration Test Setup. 9.1.7 Abrasion. 9.1.7.1 Scope.
This procedure provides a qualitative abrasive index for cushioning material. 9.1.7.2 Apparatus. The following apparatus will be used: a. A flat sheet of aluminum, with an area of not less than a total of 9 square inches (or 5806 mmІ) and having one side bright finish. The test area should be a portion of the bright surface that is clean and free from mars and scratches. 77 Downloaded from https://www.everyspec.com