N/A (no manufacturer mentioned) N/A — MIL-HDBK-304C Package Cushioning Design Handbook PDF Download

MIL-HDBK-304C 9.1.9.3 Test specimens. Each test specimen will have length and width dimensions of not less than 4 inches (100 mm). Larger specimens [8 x 8--inches (200 x 200--mm)] are recommended, machine capacity permitting. Specimen thickness should be 1 inch (25 mm) minimum. Materials less than 1 inch (25 mm) thick should be stacked to the required minimum thickness. 9.1.9.4 Conditioning. Test specimens will be conditioned per paragraph 9.1.1.4. 9.1.9.5 Prework. When required, prework material per paragraph 9.1.16. 9.1.9.6 Test Procedure.

The specimen should be loaded in a compression/tension testing machine using a strain rate not greater than 1.0 inch per minute per inch of specimen thickness (25 mm per minute for each 25 mm of specimen thickness). If the specimen has been preworked, use the specimen thickness after prework. The load should be recorded at increments small enough to obtain a minimum of 15 readings for the curve. Continue loading the specimen until at least a 50% deflection is reached and a 5 percent change in initial thickness causes a 100 percent increase in load. Then unload the specimen. A continuous curve of load versus deflection should be plotted.

Plot a compressive force displacement curve with force as the ordinate and displacement as the abscissa. 9.1.9.7 Calculations. For stress strain curves, compute the compressive stress in pounds per square inch at various points along each force displacement curve 9.1.9.7.1 Stress. Stress should be calculated as follows: f = __F__ LW (9:3) where: f = stress applied to specimen F = force exerted by the testing machine in pounds L = specimen length in inches W = specimen width in inches. 9.1.9.7.2 Strain. Strain corresponding to stress should be calculated as follows: s = _x__ (9:4) T where:

s = strain resulting from stress (f) x = cushioning material displacement by an object T = either original cushion thickness (T0), or preworked thickness (Tp), whichever applies. 9.1.9.7.3 Compression Set. Compression set should be calculated as follows: Compression Set = T - T c (100) % (9:5) T where: T = either original cushion thickness (T 0 ), or preworked thickness (Tp), whichever applies T c = specimen thickness after compression testing. 80 Downloaded from https://www.everyspec.com