U.S. Department of Defense MIL-HDBK-704-3 — NOT MEASUREMENT

Downloaded from https://www.everyspec.com MIL-HDBK-704-3 TABLE TAC303-II. Test conditions for MIL-STD-704A abnormal frequency transients. TABLE TAC303-III. Test conditions for MIL-STD-704B, C, D, E and F abnormal frequency transients.

97 Test Condition Time From Steady State Frequency to Frequency Transient Level milliseconds Frequency Transient Level Hz Duration at Frequency Transient Level Time From Frequency Transient Level to Steady State Frequency milliseconds Overfrequency Transients A 333 msec 480 Hz ½ cycle 60 msec B 333 msec 480 Hz 6.69 seconds 60 msec Underfrequency Transients C 333 msec 320 Hz ½ cycle 60 msec D 333 msec 320 Hz 6.69 seconds 60 msec Combined Transient E 333 msec 333 msec 320 Hz then 480 Hz ½ cycle ½ cycle 333 msec 333 msec Test Condition Time From Steady State Frequency to Frequency Transient Level milliseconds Frequency Transient Level Hz Duration at Frequency Transient Level Time From Frequency Transient Level to Steady State Frequency milliseconds Overfrequency Transients AA 160 msec 480 Hz ½ cycle 160 msec BB 160 msec 480 Hz 4.78 seconds 160 msec Underfrequency Transients CC 160 msec 320 Hz ½ cycle 160 msec DD 160 msec 320 Hz 4.78 seconds 160 msec Combined Transient EE 160 msec 160 msec 320 Hz then 480 Hz ½ cycle ½ cycle 160 msec 160 msec