Downloaded from https://www.everyspec.com MIL-HDBK-704-3 METHOD TAC401 Emergency Steady State Limits for Voltage and Frequency POWER GROUP: Three Phase, 400 Hz, 115 V AIRCRAFT ELECTRICAL OPERATING CONDITION: Emergency PARAMETER: Emergency Steady State Limits for Voltage and Frequency 1. Scope. 1.1 Purpose. This test procedure is used to verify that three phase, 115 Volt, 400 Hz power utilization equipment operates and maintains specified performance when provided power with voltage and frequency at that the Emergency Low Steady State (ELSS) limits and the Emergency High Steady State (EHSS) limits as specified in the applicable edition(s) of MIL-STD-704. 2. Validation criteria.
The utilization equipment is considered to have passed if the utilization equipment operates and maintains performance as specified in the utilization equipment performance specification document for emergency aircraft electrical conditions when supplied input power of voltage and frequency at the specified emergency steady state limits of the applicable edition(s) of MIL-STD-704 and as noted in table TAC401-I.
The utilization equipment must maintain specified performance for a length of time that confirms the utilization equipment can continuously operate at the emergency steady state voltage and frequency limits and should be, not less than thirty (30) minutes for each of the test conditions. Unless otherwise specified in the utilization equipment performance specification document, the utilization equipment must demonstrate re-start at the emergency steady state voltage and frequency limits.
Unless otherwise specified in the utilization equipment performance specification document, the utilization must automatically return to the performance specified for normal aircraft electrical conditions when the power returns to within normal limits. The utilization equipment must not suffer damage or cause an unsafe condition. TABLE TAC401-I. MIL-STD-704 emergency limits for steady state voltage and frequency. 1/ For MIL-STD-704E and F, performance of test method TAC102 will constitute performance of test method TAC401.
101 Emergency Limit 704A 704B 704C 704D 1/ 704E 1/ 704F Voltage ELSS 104 V 102 V 104 V 104 V 108 V 108 V Voltage EHSS 122 V 124 V 122 V 122 V 118 V 118 V Frequency ELSS 360 Hz 360 Hz 360 Hz 360 Hz 393 Hz 393 Hz Frequency EHSS 440 Hz 440 Hz 440 Hz 440 Hz 407 Hz 407 Hz