U.S. Department of Defense MIL-HDBK-704-3 — NOT MEASUREMENT

Downloaded from https://www.everyspec.com MIL-HDBK-704-3 METHOD TAC601 Power Failure (Three Phase) POWER GROUP: Three Phase, 400 Hz, 115 V AIRCRAFT ELECTRICAL OPERATING CONDITION: Power Failure PARAMETER: Power Failure (Three Phase) 1. Scope 1.1. Purpose. This test procedure is used to verify that three phase, 115 Volt, 400 Hz power utilization equipment operates and maintains specified performance when subjected to three phase power failures as specified in the applicable edition(s) of MIL-STD-704. 2. Validation criteria.

The utilization equipment is considered to have passed if the utilization equipment operates and maintains performance as specified in the utilization equipment performance specification document for power failure aircraft electrical conditions when subjected to three phase power failures as specified by the applicable edition(s) of MIL-STD-704 and as noted in table TAC601-I. The utilization equipment must maintain the specified performance during the three phase power failures.

Unless otherwise specified in the utilization equipment performance specification document, the utilization equipment must automatically return to the performance specified for normal aircraft electrical conditions when the power returns to within normal limits. The utilization equipment must not suffer damage or cause an unsafe condition. TABLE TAC601-I. MIL-STD-704 power failure limits. 3. Apparatus. The test equipment should be as follows: a. Programmable AC power supply b. True RMS voltmeter c. Frequency counter d. Oscilloscope 4. Test setup. Configure the test setup as shown in figure TAC601-1.

Measurements, except current, must be made within 10 cm of the input power terminals of the UUT. 107 Limit 704A 704B 704C 704D 704E 704F Power Failure 7 sec Figure 3 Curve 4 MIL-STD- 704A 7 sec Figure 5 MIL-STD- 704B 7 sec Figure 7 MIL-STD- 704C 7 sec Figure 7 MIL-STD- 704D 7 sec Figure 6 MIL-STD- 704E 7 sec Figure 4 MIL-STD- 704F