U.S. Department of Defense MIL-HDBK-704-3 — NOT MEASUREMENT

Downloaded from https://www.everyspec.com MIL-HDBK-704-3 METHOD TAC602 One and Two Phase Power Failures POWER GROUP: Three Phase, 400 Hz, 115 V AIRCRAFT ELECTRICAL OPERATING CONDITION: Power Failure PARAMETER: One and Two Phase Power Failures 1. Scope. 1.1. Purpose. This test procedure is used to verify that three phase, 115 Volt, 400 Hz power utilization equipment operates and maintains specified performance when subjected to one and two phase power failures (7 seconds and indefinitely) as specified in the applicable edition(s) of MIL-STD-704. 2. Validation criteria.

The utilization equipment is considered to have passed if the utilization equipment operates and maintains performance as specified in the utilization equipment performance specification document for power failure aircraft electrical conditions when subjected to power failures as specified by the applicable edition(s) of MIL-STD-704 and as noted in table TAC602-I. The utilization equipment must maintain the specified performance during one and two phase power failures.

The utilization equipment must maintain specified performance for a length of time that confirms the utilization equipment can continuously operate with one and two phase power failures and should be not less than thirty (30) minutes for each of the test conditions. Unless otherwise specified in the utilization equipment performance specification document, the utilization equipment must automatically return to the performance specified for normal aircraft electrical conditions when the power returns to within normal limits. The utilization equipment must not suffer damage or cause an unsafe condition. TABLE TAC602-I. MIL-STD-704 power failure limits. 3. Apparatus.

The test equipment should be as follows: a. Programmable AC power supply b. True RMS voltmeter c. Frequency counter d. Oscilloscope 111 Limit 704A 704B 704C 704D 704E 704F Single Phase and Two Phase Power Failure 7 sec and indefinitely Figure 3 Curve 4 MIL-STD- 704B 7 sec and indefinitely Figure 5 MIL-STD- 704B 7 sec and indefinitely Figure 7 MIL-STD- 704C 7 sec and indefinitely Figure 7 MIL-STD- 704D 7 sec and indefinitely Figure 6 MIL-STD- 704E 7 sec and indefinitely Figure 4 MIL-STD- 704F